Multi-Conductor Cables OLFLEX FLAT 8/4C YE
- 811238
- LAPP
-
1.000:
12,56 €
-
Non-Stocked
|
Mouser Part No
58-811238
|
LAPP
|
Multi-Conductor Cables OLFLEX FLAT 8/4C YE
|
|
Non-Stocked
|
|
Min.: 1.000
Mult.: 1.000
|
|
|
|
4 Conductor
|
|
8 AWG
|
|
|
Polyvinyl Chloride (PVC)
|
Copper
|
|
600 V
|
|
|
|
Multi-Conductor Cables OLFLEX FLAT 8/4C BK
- 811270
- LAPP
-
1.000:
12,56 €
-
Non-Stocked
|
Mouser Part No
58-811270
|
LAPP
|
Multi-Conductor Cables OLFLEX FLAT 8/4C BK
|
|
Non-Stocked
|
|
Min.: 1.000
Mult.: 1.000
|
|
|
|
4 Conductor
|
|
8 AWG
|
|
|
Polyvinyl Chloride (PVC)
|
Copper
|
|
600 V
|
|
|
|
Multi-Conductor Cables OLFLEX FD 890 8/4C BK COND
- 8908044
- LAPP
-
1.000:
7,24 €
-
Non-Stocked
|
Mouser Part No
58-8908044
|
LAPP
|
Multi-Conductor Cables OLFLEX FD 890 8/4C BK COND
|
|
Non-Stocked
|
|
Min.: 1.000
Mult.: 1.000
|
|
|
Unshielded
|
4 Conductor
|
|
8 AWG
|
19.202 mm (0.756 in)
|
Black
|
Polyvinyl Chloride (PVC)
|
Copper
|
|
600 V
|
|
|
|
Multi-Conductor Cables OLFLEX FD 890 CY 8/4C BK COND
- 8908044S
- LAPP
-
1.000:
11,31 €
-
Non-Stocked
|
Mouser Part No
58-8908044S
|
LAPP
|
Multi-Conductor Cables OLFLEX FD 890 CY 8/4C BK COND
|
|
Non-Stocked
|
|
Min.: 1.000
Mult.: 1.000
|
|
|
Shielded
|
4 Conductor
|
|
8 AWG
|
22.403 mm (0.882 in)
|
Black
|
Polyvinyl Chloride (PVC)
|
Copper
|
|
600 V
|
|
|
|
Multi-Conductor Cables Series SF 8 AWG 4 Conductor cable, Foil/Braid, 1000ft Orange
Alpha Wire SF61108CY OR001
- SF61108CY OR001
- Alpha Wire
-
1:
13.952,89 €
-
Non-Stocked Lead-Time 7 Weeks
|
Mouser Part No
602-SF61108CYOR001
|
Alpha Wire
|
Multi-Conductor Cables Series SF 8 AWG 4 Conductor cable, Foil/Braid, 1000ft Orange
|
|
Non-Stocked Lead-Time 7 Weeks
|
|
Min.: 1
Mult.: 1
|
|
Power Cable
|
Shielded
|
4 Conductor
|
1000 ft
|
8 AWG
|
19.94 mm (0.785 in)
|
Orange
|
Thermoplastic Elastomer (TPE)
|
Tinned Copper
|
168 x 30
|
600 V
|
|
|
|
Multi-Conductor Cables Turboflex Duralectric L Jacket; Nickel; Wire size C; White
- 961-041-N-C-9
- Glenair
-
Non-Stocked
|
Mouser Part No
631-961041NC9
|
Glenair
|
Multi-Conductor Cables Turboflex Duralectric L Jacket; Nickel; Wire size C; White
|
|
Non-Stocked
|
|
|
|
|
Unshielded
|
95 Conductor
|
1 ft
|
8 AWG
|
5.31 mm (0.209 in)
|
White
|
|
Copper, Copper-Nickel Alloy
|
7 x 36
|
1.25 kVAC
|
|
|
|
Multi-Conductor Cables 8AWG 3C SHIELD 1000ft SPOOL BLACK
- 29504 0101000
- Belden Wire & Cable
-
Restricted Availability
|
Mouser Part No
566-29504-1000-10
|
Belden Wire & Cable
|
Multi-Conductor Cables 8AWG 3C SHIELD 1000ft SPOOL BLACK
|
|
|
|
|
|
Flexible VFD Cable
|
Shielded
|
3 Conductor
|
1000 ft
|
8 AWG
|
23.62 mm (0.93 in)
|
Black
|
Polyvinyl Chloride (PVC)
|
Tinned Copper
|
7 x 19 x 29
|
1 kV
|
|
|
|
Multi-Conductor Cables 8AWG 3C SHIELD 250ft SPOOL BLACK
- 29504 010250
- Belden Wire & Cable
-
Restricted Availability
|
Mouser Part No
566-29504-250-10
|
Belden Wire & Cable
|
Multi-Conductor Cables 8AWG 3C SHIELD 250ft SPOOL BLACK
|
|
|
|
|
|
Flexible VFD Cable
|
Shielded
|
3 Conductor
|
250 ft
|
8 AWG
|
6.53 mm (0.257 in)
|
Black
|
Polyvinyl Chloride (PVC)
|
Tinned Copper
|
7 x 19 x 29
|
1 kV
|
|
|
|
Multi-Conductor Cables 8AWG 3C SHIELD 500ft SPOOL BLACK
- 29504 010500
- Belden Wire & Cable
-
Restricted Availability
|
Mouser Part No
566-29504-500-10
|
Belden Wire & Cable
|
Multi-Conductor Cables 8AWG 3C SHIELD 500ft SPOOL BLACK
|
|
|
|
|
|
Flexible VFD Cable
|
Shielded
|
3 Conductor
|
500 ft
|
8 AWG
|
6.53 mm (0.257 in)
|
Black
|
Polyvinyl Chloride (PVC)
|
Tinned Copper
|
7 x 19 x 29
|
1 kV
|
|
|
|
Multi-Conductor Cables Belden Basics VFD, 3 Conductor 8AWG (7x16) Bare Copper XLPE Insulation M4 Color Code + 10AWG Symmetrical Segmented Ground (3 of 14AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 2000V TC-ER 90C D
- 29724C 0102500
- Belden Wire & Cable
-
Restricted Availability
-
New At Mouser
|
Mouser Part No
566-29724C0102500
New At Mouser
|
Belden Wire & Cable
|
Multi-Conductor Cables Belden Basics VFD, 3 Conductor 8AWG (7x16) Bare Copper XLPE Insulation M4 Color Code + 10AWG Symmetrical Segmented Ground (3 of 14AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 2000V TC-ER 90C D
|
|
|
|
|
|
|
Shielded
|
3 Conductor
|
|
8 AWG
|
20.2 mm (0.795 in)
|
Black
|
Polyvinyl Chloride (PVC)
|
Copper
|
7 x 16
|
2 kV
|
|
|
|
Multi-Conductor Cables Belden Basics VFD, 3 Conductor 8AWG (7x16) Bare Copper XLPE Insulation M4 Color Code + 10AWG Symmetrical Segmented Ground (3 of 14AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 2000V TC-ER 90C D
- 29724C 0105000
- Belden Wire & Cable
-
Restricted Availability
-
New At Mouser
|
Mouser Part No
566-29724C0105000
New At Mouser
|
Belden Wire & Cable
|
Multi-Conductor Cables Belden Basics VFD, 3 Conductor 8AWG (7x16) Bare Copper XLPE Insulation M4 Color Code + 10AWG Symmetrical Segmented Ground (3 of 14AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 2000V TC-ER 90C D
|
|
|
|
|
|
|
Shielded
|
3 Conductor
|
|
8 AWG
|
20.2 mm (0.795 in)
|
Black
|
Polyvinyl Chloride (PVC)
|
Copper
|
7 x 16
|
2 kV
|
|
|
|
Multi-Conductor Cables Belden Basics VFD, 3 Conductor 8AWG (7x16) Bare Copper XLPE Insulation M4 Color Code + 10AWG Symmetrical Segmented Ground (3 of 14AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 600/1000V TC-ER 9
Belden Wire & Cable 29524C 0101000
- 29524C 0101000
- Belden Wire & Cable
-
Restricted Availability
|
Mouser Part No
566-29524C0101000
|
Belden Wire & Cable
|
Multi-Conductor Cables Belden Basics VFD, 3 Conductor 8AWG (7x16) Bare Copper XLPE Insulation M4 Color Code + 10AWG Symmetrical Segmented Ground (3 of 14AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 600/1000V TC-ER 9
|
|
|
|
|
|
|
|
3 Conductor
|
1000 ft
|
8 AWG
|
|
Black
|
|
|
|
600 V
|
|
|
|
Multi-Conductor Cables Belden Basics VFD, 3 Conductor 8AWG (7x16) Bare Copper XLPE Insulation M4 Color Code + 10AWG Symmetrical Segmented Ground (3 of 14AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 600/1000V TC-ER 9
Belden Wire & Cable 29524C 0105000
- 29524C 0105000
- Belden Wire & Cable
-
Restricted Availability
|
Mouser Part No
566-29524C0105000
|
Belden Wire & Cable
|
Multi-Conductor Cables Belden Basics VFD, 3 Conductor 8AWG (7x16) Bare Copper XLPE Insulation M4 Color Code + 10AWG Symmetrical Segmented Ground (3 of 14AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 600/1000V TC-ER 9
|
|
|
|
|
|
|
|
3 Conductor
|
5000 ft
|
8 AWG
|
|
Black
|
|
|
|
600 V
|
|
|
|
Multi-Conductor Cables Belden 300% Ground Flexible VFD, 3 Conductor 8AWG (7x19x29) Tinned Copper, XLPE Insulation M4 Color Code+PVC Insulated Ground, Overall Beldfoil+Tinned Copper Braid(85%) Shield w/3-14AWG Tinned Copper Drains, Black PVC Outer Jacket, 2000V TC-ER 90C Dr
Belden Wire & Cable 29539 0101000
- 29539 0101000
- Belden Wire & Cable
-
Restricted Availability
|
Mouser Part No
566-295390101000
|
Belden Wire & Cable
|
Multi-Conductor Cables Belden 300% Ground Flexible VFD, 3 Conductor 8AWG (7x19x29) Tinned Copper, XLPE Insulation M4 Color Code+PVC Insulated Ground, Overall Beldfoil+Tinned Copper Braid(85%) Shield w/3-14AWG Tinned Copper Drains, Black PVC Outer Jacket, 2000V TC-ER 90C Dr
|
|
|
|
|
|
|
|
4 Conductor
|
1000 ft
|
8 AWG
|
|
Black
|
|
|
|
2 kV
|
|
|
|
Multi-Conductor Cables Belden 300% Ground Flexible VFD, 3 Conductor 8AWG (7x19x29) Tinned Copper, XLPE Insulation M4 Color Code+PVC Insulated Ground, Overall Beldfoil+Tinned Copper Braid(85%) Shield w/3-14AWG Tinned Copper Drains, Black PVC Outer Jacket, 2000V TC-ER 90C Dr
Belden Wire & Cable 29539 0105000
- 29539 0105000
- Belden Wire & Cable
-
Restricted Availability
|
Mouser Part No
566-295390105000
|
Belden Wire & Cable
|
Multi-Conductor Cables Belden 300% Ground Flexible VFD, 3 Conductor 8AWG (7x19x29) Tinned Copper, XLPE Insulation M4 Color Code+PVC Insulated Ground, Overall Beldfoil+Tinned Copper Braid(85%) Shield w/3-14AWG Tinned Copper Drains, Black PVC Outer Jacket, 2000V TC-ER 90C Dr
|
|
|
|
|
|
|
|
4 Conductor
|
5000 ft
|
8 AWG
|
|
Black
|
|
|
|
2 kV
|
|
|
|
Multi-Conductor Cables 8AWG 4C SHIELD 1000ft SPOOL CHROME
Belden Wire & Cable 7450WS 0601000
- 7450WS 0601000
- Belden Wire & Cable
-
Restricted Availability
|
Mouser Part No
566-7450WS-1000-60
|
Belden Wire & Cable
|
Multi-Conductor Cables 8AWG 4C SHIELD 1000ft SPOOL CHROME
|
|
|
|
|
|
Automation and Process Control
|
Shielded
|
3 Conductor
|
1000 ft
|
8 AWG
|
|
Chrome
|
|
Copper
|
|
600 V
|
|
|
|
Multi-Conductor Cables 8AWG 4C SHIELD 250ft SPOOL CHROME
Belden Wire & Cable 7450WS 060250
- 7450WS 060250
- Belden Wire & Cable
-
Restricted Availability
|
Mouser Part No
566-7450WS-250-60
|
Belden Wire & Cable
|
Multi-Conductor Cables 8AWG 4C SHIELD 250ft SPOOL CHROME
|
|
|
|
|
|
Automation and Process Control
|
Shielded
|
3 Conductor
|
250 ft
|
8 AWG
|
|
Chrome
|
|
Copper
|
|
600 V
|
|
|
|
Multi-Conductor Cables 2 #8 PVC/NYL TPE
Belden Wire & Cable 8808H B591000
- 8808H B591000
- Belden Wire & Cable
-
Restricted Availability
|
Mouser Part No
566-8808HB591000
|
Belden Wire & Cable
|
Multi-Conductor Cables 2 #8 PVC/NYL TPE
|
|
|
|
|
|
|
|
2 Conductor
|
1000 ft
|
8 AWG
|
|
|
|
|
|
|
|
|
|
Multi-Conductor Cables 2 #8 PVC/NYL PVC
Belden Wire & Cable 8808WB 0101000
- 8808WB 0101000
- Belden Wire & Cable
-
Restricted Availability
|
Mouser Part No
566-8808WB0101000
|
Belden Wire & Cable
|
Multi-Conductor Cables 2 #8 PVC/NYL PVC
|
|
|
|
|
|
|
|
2 Conductor
|
1000 ft
|
8 AWG
|
|
Black
|
|
|
|
|
|
|
|
Multi-Conductor Cables 8AWG 2C SPIR SHL 600V PRICE PER FT
TE Connectivity / Raychem 44B5821-8-9/96-9CS1401
- 44B5821-8-9/96-9CS1401
- TE Connectivity / Raychem
-
500:
10,47 €
-
Non-Stocked Lead-Time 15 Weeks
|
Mouser Part No
650-551301-000
|
TE Connectivity / Raychem
|
Multi-Conductor Cables 8AWG 2C SPIR SHL 600V PRICE PER FT
|
|
Non-Stocked Lead-Time 15 Weeks
|
|
Min.: 500
Mult.: 1
|
No
|
|
Shielded
|
|
1 ft
|
8 AWG
|
|
|
|
|
|
600 V
|
|