17 mm Board Mount Current Sensors

Results: 41
Select Image Part # Mfr. Description Datasheet Availability Pricing (EUR) Filter the results in the table by unit price based on your quantity. Qty. RoHS ECAD Model Current Rating Sensor Type Response Time Accuracy Frequency Range Operating Supply Voltage Output Type
Tamura Board Mount Current Sensors CURRENT SENSOR ( 60A; 15V) 3.277In Stock
Min.: 1
Mult.: 1

60 A Open Loop 5 us 0 Hz to 100 kHz 15 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 3A; 15V) 1.023In Stock
Min.: 1
Mult.: 1

3 A Open Loop 5 us 0 Hz to 100 kHz 15 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 50A; 15V) 456In Stock
Min.: 1
Mult.: 1

50 A Open Loop 5 us 0 Hz to 100 kHz 15 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 15A; 15V) 194In Stock
600Expected 1/18/2027
Min.: 1
Mult.: 1

15 A Open Loop 5 us 0 Hz to 100 kHz 15 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 5A; 15V) 157In Stock
1.200Expected 10/23/2026
Min.: 1
Mult.: 1

5 A Open Loop 5 us 0 Hz to 100 kHz 15 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 10A; 15V) 464In Stock
600Expected 3/31/2027
Min.: 1
Mult.: 1

10 A Open Loop 5 us 0 Hz to 100 kHz 15 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 20A; 15V) 487In Stock
Min.: 1
Mult.: 1

20 A Open Loop 5 us 0 Hz to 100 kHz 15 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 25A; 15V)
600Expected 11/24/2026
Min.: 1
Mult.: 1

25 A Open Loop 5 us 0 Hz to 100 kHz 15 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 3A; +5V) Non-Stocked Lead-Time 24 Weeks
Min.: 1.200
Mult.: 1.200

3 A Open Loop 5 us 0 Hz to 100 kHz 5 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 3A;+5V; 0.625V GAIN) Non-Stocked Lead-Time 24 Weeks
Min.: 1.200
Mult.: 1.200

3 A Open Loop 5 us 0 Hz to 100 kHz 5 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 3A;+12V) Non-Stocked Lead-Time 24 Weeks
Min.: 1.200
Mult.: 1.200

3 A Open Loop 5 us 0 Hz to 100 kHz 12 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 5A;+5V) Non-Stocked Lead-Time 24 Weeks
Min.: 1.200
Mult.: 1.200

5 A Open Loop 5 us 0 Hz to 100 kHz 5 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 5A;+5V; 0.625V GAIN) Non-Stocked Lead-Time 24 Weeks
Min.: 1.200
Mult.: 1.200

5 A Open Loop 5 us 0 Hz to 100 kHz 5 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 5A;+12V) Non-Stocked Lead-Time 24 Weeks
Min.: 1.200
Mult.: 1.200

5 A Open Loop 5 us 0 Hz to 100 kHz 12 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 10A; +5V) Non-Stocked Lead-Time 24 Weeks
Min.: 600
Mult.: 600

10 A Open Loop 5 us 0 Hz to 100 kHz 5 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 10A; +5V; 0.625V GAIN) Non-Stocked Lead-Time 24 Weeks
Min.: 600
Mult.: 600

10 A Open Loop 5 us 0 Hz to 100 kHz 5 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 10A; +12V) Non-Stocked Lead-Time 24 Weeks
Min.: 600
Mult.: 600

10 A Open Loop 5 us 0 Hz to 100 kHz 12 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 15A; +5V) Non-Stocked Lead-Time 24 Weeks
Min.: 600
Mult.: 600

15 A Open Loop 5 us 0 Hz to 100 kHz 5 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 15A; +5V; 0.625V GAIN) Non-Stocked Lead-Time 24 Weeks
Min.: 600
Mult.: 600

15 A Open Loop 5 us 0 Hz to 100 kHz 5 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 15A; +12V) Non-Stocked Lead-Time 24 Weeks
Min.: 600
Mult.: 600

15 A Open Loop 5 us 0 Hz to 100 kHz 12 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 20A; +5V) Non-Stocked Lead-Time 24 Weeks
Min.: 600
Mult.: 600

20 A Open Loop 5 us 0 Hz to 100 kHz 5 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 20A; +5V; 0.625V GAIN) Non-Stocked Lead-Time 24 Weeks
Min.: 600
Mult.: 600

20 A Open Loop 5 us 0 Hz to 100 kHz 5 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 20A; +12V) Non-Stocked Lead-Time 24 Weeks
Min.: 600
Mult.: 600

20 A Open Loop 5 us 0 Hz to 100 kHz 12 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 25A; +5V) Non-Stocked Lead-Time 24 Weeks
Min.: 600
Mult.: 600

25 A Open Loop 5 us 0 Hz to 100 kHz 5 V Analog - Voltage
Tamura Board Mount Current Sensors CURRENT SENSOR ( 25A; +5V; 0.625V GAIN) Non-Stocked Lead-Time 24 Weeks
Min.: 600
Mult.: 600

25 A Open Loop 5 us 0 Hz to 100 kHz 5 V Analog - Voltage